Catalog pricing shown. Please Sign In to see your pricing.

Arcoaire HP Single Phase Split System Multi Stg 1.5 Ton 25k BTU Coil 96Pct Furnace 060 MBH 16 SEER2

Arcoaire HP Single Phase Split System Multi Stg 1.5 Ton 25k BTU Coil 96Pct Furnace 060 MBH 16 SEER2
Kit Includes whip 6' 3/4" 6GA, No Vent Caps, 3" Plastic Pad, Surge Protector, 50' Line Set 1/2" Insul, PVC Adapters/Fittings, 6" Heat Pump Riser, PVC Trap Kit, Furnace Leveler, 2H/2C Thermostat, Disconnect

This retail set contains

Vendor Name:
Arcoaire
URI Part Number:
Arcoaire HP Single Phase Split System Multi Stg 1.5 Ton 25k BTU Coil 96Pct Furnace 060 MBH 16 SEER2
Shipping Weight (Lbs.):
200
Energy Star:
Not Energy Star Compliant
Heating Input (BTUH):
060 MBH Heat
Includes:
DLCURAH18ABK, F96VTN0601714A, EAM4X25L17A, HPKIT40
Nominal Capacity (BTUH):
18000
Cooling Efficiency (EER2):
10.5
Cooling Efficiency (SEER2):
16
Heating Efficiency HSPF2:
8.5 HSPF2
System Indoor Type:
Gas Furnace
System Outdoor Type:
Multi Stage
System Coil Configuration:
Multi Position "A" Coil
Furnace Efficiency:
96
System Nominal Tons:
1.5 Ton
AHRI System Number:
211260967
Heat Pump, Single Phase, Split Gas Furnace Multi Stage, Multi Position "A" Coil DLCURAH/F96VTN/EAM4X

Heat Pump Inverter
  • Utilize expansion device on the indoor unit
  • Insulate suction line only
  • Anti corrosion coating
  • Built in algorithm learns and adapts
  • Monitors suction pressure/temperature (super heat) to regulatecompressor speed
  • Field adjustable timer (ramps up to 100% if thermostat not satisfied)
  • Automatically ramps up/down 30-120% rated capacity
  • Field set sw 1-3 to A/C only
  • Low ambient cooling to -22°F
  • Pre charged for 25' tubing
Gas Furnace
  • Two-stage heating operation
  • Two-speed induced draft combustion blower
  • Supports single- and two-stage cooling units
  • Dehumidification feature (A/C)
  • Fully insulated steel cabinet
  • Certified to leak 2% or less of nominal air conditioning CFM delivered (when pressurized to 1 inch water column with all present air inlets, air outlets, and condensate drain port(s) sealed)
  • VCT Variable Speed Constant Torque Motor
  • Aluminized steel RPJ primary heat exchanger
  • Stainless steel secondary heat exchanger
  • Direct ignition with Silicon Nitride ignitor
  • Direct vent (2-pipe), single-pipe venting, or ventilated combustion air
  • 35” (889mm) high , for ease of installation
  • Four position - upflow/downflow/horizontal (left/right) installation
  • At least twelve different venting configurations
  • Through the casing flue pipe for counterflow or horizontal applications with accessory (order separately)
  • Self-configuring and communicating control
  • Concentric vent available
  • Twining Capable (select size) w/ kit
Evaporator Coil
  • Thermostatic Expansion Valve (TXV)
  • Multi-position airflow design
  • Sturdy galvanized steel cabinet
  • Non-ozone-depleting R-410A refrigerant
  • Capacity: 1.5 - 5 tons
  • Cased A coil design for efficient heat transfer in a compact size
  • Corrosion-resistant all-aluminum coil
  • Fully insulated cabinet